Basement & Radon Solutions installed a radon mitigation system for Hailey & Kazuto. We connected the existing radon piping system installed below our encapsulated ground liner to a 4″ PVC suction pipe that was extended to the exterior of the home where the radon fan was installed. The radon vent pipe was mounted to the exterior wall and terminated above the roofline to safely get rid of the gas. The manometer gauge (homeowner radon fan monitoring vacuum gauge) was installed on the suction line of the system in the crawlspace. We also installed a Radon System Alarm. They are now required on all newly installed residential radon systems. This unit is a vacuum monitoring device utilizing piezo resistive pressure sensor (PPS) technology. This alarm will provide an audible and visual indication to alert the homeowner when the radon system is not moving sufficient air in the event of a power loss to the system. Lastly, we preformed a post radon test that came back at 1.4 pCi/l!
It was a pleasure helping Hailey & Kazuto make their new home happy, healthy & safe!